Electronaut M63 Bedienungsanleitung Seite 8

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 17
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 7
USER’S MANUAL
Electronaut M63 Vacuum Tube Microphone/Instrument Preamplifier
7
E L E C T R O N A U T C O M P A N Y
Helvetica neue condensed black
tracked like crazy, like 400 or something.
Usual logo is without concentric circles.
Website has the concentric circles.
R 1
R 2
R 3
R 4
C 1
D 1
D 2
C 2C 5
C 4 C 3
R 5
R 6
R 7
R 8
D 5
D 7
C 9
R I G H T
D 6
D 8
D 4
C 7
C 6
C 8
L E F T
Q 1Q 2
Q 4
T C
L I N E V O L T A G E S E L E C T
1 2 X 4
R B l e e d e r
Q 3
R 9
C 1 1
C 1 2
C 1 0
D 3
P O W E R
1 2 V D C
1 2 A Y 7
1 2 A U 7
S W 4 S W 5
R 3
R 4
R 5
R 8
C 1 4 C 1 3
C 1 2
D 5
S W 7
S W 6
C 2
C 3
C 6
M C
R 7
R 6
C 1 6
R T
R 9
C 1
C 5
C 8
R 1 0
R 1 1
R 1 2
R 1 3
R 1 4
R 1 5
R 2 5
R 1 7
R 1 8
R 1 6
R 2 6
R 2 8
R 3 0
R 2 9
R 3 2
R 2 2
R 1 9
R 2 1
R 2 0
C 9
C 1 0
D 1
D 2
D 4
D 3
L L 1 6 3 6
M i c I n p u t R i g h t
L i n e O u t p u t R i g h t
T L 0 7 2
R 2 7
C 1 5
R 2 4
R 2 3
C 1 1
R 2
R 1
0 V
H e a d e r - 1 2
H e a d e r - 4
C 7
C 4
L L 1 6 7 6
1 2 A U 7
1 2 A Y 7
S W 4S W 5
R 3
R 4
R 5
R 8
C 1 5
C 1 4 C 1 3
C 1 2
D 5
S W 7
S W 6
C 2
C 3
C 6
M C
R 7
R 6
C 1 6
R T
R 9
C 1
C 5
C 8
R 1 0
R 1 1
R 1 2
R 1 3
R 1 4
R 1 5
R 2 5
R 2 7
R 1 7
R 1 8
R 1 6
R 2 6
R 2 8
R 3 0
R 2 9
R 2 2
R 1 9
R 2 1
R 2 0
C 9
C 1 0
C 1 1
D 1
D 2
D 4
D 3
L L 1 6 3 6
M i c I n p u t R i g h t
L i n e O u t p u t R i g h t
T L 0 7 2
R 2 4
R 3 2
R 2 3
R 1
R 2
0 V
H e a d e r - 4
H e a d e r - 1 2
C 7
C 4
L L 1 6 7 6
Meter
Calibration
Potentiometers
Ground Lift
Switches
Phantom Power
Voltage Adjuster
12AY7/6072A
Vacuum Tube
12AU7/ECC82
Vacuum Tube
12AY7/6072A
Vacuum Tube
12AU7/ECC82
Vacuum Tube
12X4
Vacuum Tube
AC Mains
Voltage Selector
Figure 1
INSTALLATION
The M63 is designed to be mounted in a standard 19” equipment rack, occupying three units (3U) of space,
or 5.25 inches, but additional space above and below is recommended for improved airflow and cooler
operation. Alternatively, the M63 can be placed on a table or other level surface, but care must be given to prevent
covering up or blocking the ventilation holes on the top and bottom of the unit. The M63 is designed to run fairly
cool considering the number of tubes and the size of the power supply, but it is normal for the unit to be warm to
the touch. The M63 should never be so hot as to make it impossible to leave your hand on the top cover for an
extended period of time.